SYPG Series
Flange Plate Output Reducer
Distinctive flange-plate output with great mounting freedom; shorter body and cross-roller carrier bearing for shock resistance.
- Frame size64–110
- Ratio4–100
- Backlash1–3 arcmin (P1) / 3–5 arcmin (P2)
| Frame size | 64–110 |
|---|---|
| Ratio | 4–100 |
| Backlash | 1–3 arcmin (P1) / 3–5 arcmin (P2) |
| Available frame sizes | 64 / 90 / 110 |
| Single stage ratio (L1) | 3, 4, 5, 7, 10 |
| Two stage ratio (L2) | 12, 15, 16, 20, 25, 28, 30, 35, 40, 50, 70, 100 |
| Lubrication | Lifetime lubricated, maintenance-free |
| Protection | IP65 |
| Mounting | Any orientation |
| Frame size | 64 / 90 / 110 |
|---|---|
| Rated output torque T₂N (N·m) | 64: 35–50 90: 80–125 110: 160–350 |
| Acceleration torque T₂B (N·m) | 1.5 × rated torque |
| Emergency stop torque T₂NOT (N·m) | 3 × rated torque |
| Rated input speed (rpm) | 64: 4000 90: 3000 110: 3000 |
| Max input speed (rpm) | 64: 6000 90: 6000 110: 4500–6000 |
| Efficiency | L1 ≥95% / L2 ≥90% |
| Noise (dB) | 64: ≤58 90: ≤60 110: ≤65 |
Each figure is prefixed with its frame size. Rated output torque varies with ratio; figures show the range across the full ratio span. Please contact us for values at specific ratios. Protection rating IP65, ambient −10°C to 90°C, average life 20,000 h.
| Frame size | 64 / 90 / 110 |
|---|
Symbols in the drawing correspond to the dimensions in the table below. Tell us your motor brand and model, and we can provide matching input connection dimensions.